SKU : SC-LS-EC12-OLD-SP
1 Sold
5.0 / 5 (1 Reviews)
Quantity
Short Description
The LASWIM EC12 produces up to 12 g of chlorine per hour and is rated for pools up to 50 m³. Its integrated controller and cell save installation space and allow easy access for maintenance. This cream-coloured old-model unit is newly assembled from spare parts and ships in a standard carton without the original manufacturer’s box. Please confirm the included accessories and warranty terms before ordering. (Update 16/07/2026)
Up to 12 g/h chlorine output · For pools up to 50 m³ under the referenced specifications
The EC12 uses electrolysis to generate chlorine from salt dissolved in pool water. Its controller and electrolytic cell are combined in one compact unit, and the cell plates can be accessed for maintenance. The chlorinator must operate with a functioning circulation and filtration system. Pool water still needs regular testing and chemical balancing.
| Model / SKU | LASWIM EC12 (Old Model) / SC-LS-EC12-OLD-SP |
|---|---|
| Maximum chlorine output | 12 g/h |
| Maximum pool volume | 50 m³; suitability depends on actual pool conditions |
| Operating voltage / current | DC 24 V / 4 A in the manufacturer's EC12 specifications; verify the supplied adapter's label |
| Water connections | 1.5 in / 50 mm nominal; check the actual unions before installation |
| Reference dimensions | 378 × 122 × 152 mm in the manufacturer's EC Series specifications |
| Condition / packaging | Newly assembled from spare parts · Cream-coloured unit · No original factory box |
50 m³ is a reference maximum, not a guarantee of sufficient chlorine in every pool. Allow for sunlight, bather load, water conditions and pump runtime when selecting a chlorinator.
Install in the pool circulation line after the pump and filter, following the manual. Check the flow direction and make sure enough water passes through the cell. Plan any bypass and valves for the actual site layout.
02 · Electrical supplyHave a qualified installer check the power supply and the adapter supplied with the unit. Provide appropriate earth-leakage protection and ensure the chlorinator cannot run while the circulation pump is off.
Choose a well-ventilated location. Protect electrical parts from rain, excessive moisture and splashes, and leave room to remove the cell plates.
04 · Water checkMeasure salinity and water chemistry before starting chlorine production. Run the pump and confirm adequate water flow through the unit.
The EC Series manual gives a reference salinity of approximately 3,500 ppm, equivalent to 3.5 kg of salt per cubic metre of water when starting from zero salinity. Use suitable sodium chloride pool salt without inappropriate additives. Always measure the existing salinity before adding more.
Switch off the chlorinator while adding salt, but keep the circulation pump running. Distribute the salt around the pool rather than leaving it in a pile. The manual recommends 24 hours of circulation, followed by another salinity test, before restarting the chlorinator. Test free chlorine and pH regularly, then adjust output and operating time according to actual readings.
| Code | Meaning | Initial check |
|---|---|---|
| E2 | Water temperature outside the operating range | Check water temperature and the sensor |
| E3 | Insufficient water in the cell | Check the pump, valves, trapped air and sensor |
| E4 | High salt level | Measure salinity independently before taking action |
| E5 | Low salt level | Measure salinity before calculating any salt addition |
For E1 and E6EC, consult the manual or a service technician. These codes may relate to temperature, sensors, power supply, the cell or electronic circuits. Never open the electrical housing while energized.
Inspect the cell periodically and clean it when scale is present. The automatic cleaning function reduces scale buildup but does not replace inspection. Before removing the cell, disconnect power, stop the pump, close the relevant valves and release pipe pressure. If a cell-cleaning solution is needed, follow the EC Series manual and the chemical's safety instructions. Do not scrape the titanium plates with metal tools.
The Thai description says it is newly assembled from spare parts. It is a cream-coloured EC12 old model without its original factory box. Request photos of the actual unit before ordering.
The supplied parts are not itemized in the attached description. Ask the seller to confirm the package contents and the adapter's rating before paying.
50 m³ is the reference maximum for EC12. Sunlight, bather load, chlorine demand and circulation time also matter. A pool with high demand may require a larger chlorinator.
The Thai description says the warranty matches that of the blue model, but it does not state the duration or detailed terms. Ask for written confirmation before ordering.
EC Series manual (Thai): Open the user manual · Technical data is based on the LASWIM EC Series specifications. Check the labels on the actual equipment supplied.