SKU : SC-LS-EC16-B
0 Sold
no reviews
Quantity
Short Description
The EC16 salt chlorinator produces up to 16 g of chlorine per hour and is suitable for pools up to 68 m³. Its compact design requires little installation space and is easy to operate and maintain. The controller is mounted on the cell assembly.
Package dimensions: 16 × 34 × 25.5 cm
Gross weight including packaging: 2.87 kg
Updated: 04/03/2026
Easy to operate · Compact installation · Protective functions for abnormal water conditions

PRODUCT OVERVIEW
LASWIM EC Plus uses electrolysis to generate sanitizing chlorine from salt dissolved in pool water. Its controller and cell are integrated into one unit, reducing the installation footprint and the number of connection points. It suits small to medium pools, while regular testing and balancing of pool water remain necessary.
MODEL COMPARISON
| Model | Maximum chlorine output | Maximum pool volume* | Output voltage | Operating current |
|---|---|---|---|---|
| EC Plus 8 | 8 g/h | 35 m³ | DC 24 V | 4 A |
| EC Plus 12 | 12 g/h | 50 m³ | DC 24 V | 4 A |
| EC Plus 16 | 16 g/h | 68 m³ | DC 24 V | 4 A |
| EC Plus 20 | 20 g/h | 85 m³ | DC 24 V | 4 A |
| EC Plus 30 | 30 g/h | 127 m³ | DC 29 V | 6 A |
*Maximum pool volumes are manufacturer catalog reference figures for model selection. Allow approximately 20–30% extra output capacity and consider actual use, sun exposure, pump run time, and water quality. Check the model label and supplied adapter before installation.
INSTALLATION GUIDANCE
Install in the pool return line downstream of the pump and filter, following the manufacturer's flow direction. If a bypass is used, provide suitable flow-control and isolation valves for the actual piping layout.
02 · Connection sizeCheck the 1.5 in / 50 mm unions against the piping before making permanent connections, and leave room to remove the cell for maintenance.
Use the power supply specified for the model and install residual-current protection in accordance with local requirements. Have a qualified person install it and check its interlock with the pump.
04 · Installation locationChoose a ventilated location and avoid rain, intense sunlight, and splashing as specified in the product manual.
Measure free chlorine, pH, and actual salinity before adjusting output. The chlorinator does not automatically measure and control every water-quality parameter. If salt must be added, use pool-grade salt as specified in the manual and allow it to dissolve throughout the pool before generating chlorine.
Inspect the cell for scale on the maintenance schedule. Disconnect power, stop the pump, and release pipe pressure before removing any components. If cell-cleaning solution is required, follow the dilution and procedure in the supplied model's manual, wear protective equipment, and avoid scraping titanium plates with metal tools.

The images are illustrative. Follow the manual for the actual model supplied for installation clearances, plumbing, and electrical connections.