Laswim EC Series, Laswim salt chlorinator, E3 error code, salt chlorinator no water, air in pool pipes, water level sensor

Laswim EC Series Salt Chlorinator Showing E3: What Should You Check?
The E3 code means there is no water in the unit. The unit needs enough water to produce chlorine.

No Water in the Unit
Check both the water supply to the unit and the water level detection device, in that order.
Check in Order
Check the pump and valves
Is the circulation pump running? Are the valves in the operating position? Make sure water is actually reaching the unit.
Check for leaks and air in the pipes
The manual says to check for leaks or air in the pipes, as these can leave too little water in the unit. Fix the cause and make sure the system has water normally before use.
Fix the water system first
Fix the pump, valves, leaks or air in the pipes so the system has water normally, then start the unit.
Have a technician check the water level detection device
Including inspection and cleaning per the manual when needed.
E3 Doesnt Automatically Mean the Water Level Detector Is Faulty
You need to tell which case it is to fix the right problem.
Switch off and disconnect power before removing equipment or doing maintenance, and have a technician carry out internal inspection.
Frequently Asked Questions
What does the E3 code mean on a Laswim salt chlorinator?
E3 means there is no water in the unit. The unit needs enough water to produce chlorine.
What should I check first for E3?
Start by checking that the circulation pump is running, the valves are in the operating position, and there are no leaks or air in the pipes.
Water is reaching the unit but E3 still shows. What now?
Have a technician check the water level detection device, including inspection and cleaning per the manual when needed.
Can I keep running the unit with E3 showing?
No. Never force the unit to run without water. Fix the cause so the system has water normally before use.
Need Help With an Initial Diagnosis?
Send us a photo of the display and the installation, and let us know whether the pump is running and water is reaching the unit.