Salt Chlorinator Error Codes | Laswim EC Series

Laswim EC Series Salt Chlorinator Showing E3: What Should You Check?

The E3 code means there is no water in the unit. The unit needs enough water to produce chlorine.

E3
Meaning per the manual

No Water in the Unit

Check both the water supply to the unit and the water level detection device, in that order.

Check in Order

1

Check the pump and valves

Is the circulation pump running? Are the valves in the operating position? Make sure water is actually reaching the unit.

2

Check for leaks and air in the pipes

The manual says to check for leaks or air in the pipes, as these can leave too little water in the unit. Fix the cause and make sure the system has water normally before use.

 
Water supply still insufficient

Fix the water system first

Fix the pump, valves, leaks or air in the pipes so the system has water normally, then start the unit.

3 Water present, but E3 still shows

Have a technician check the water level detection device

Including inspection and cleaning per the manual when needed.

E3 Doesnt Automatically Mean the Water Level Detector Is Faulty

You need to tell which case it is to fix the right problem.

Case A
The unit really has no water
Case B
Water is present, but the detection device is malfunctioning
Never Force the Unit to Run Without Water

Switch off and disconnect power before removing equipment or doing maintenance, and have a technician carry out internal inspection.

Other Laswim EC Series codes
E1 Heat sink temperature too high E2 Water temperature outside 1045°C E4 Salt too high E5 Salt too low E6 Controller temperature sensor fault E7 Water temperature sensor fault E8 Input voltage too high or too low E9 Excessive output current EA Electrode fault EB System memory chip fault EC System detection circuit fault

Frequently Asked Questions

What does the E3 code mean on a Laswim salt chlorinator?

E3 means there is no water in the unit. The unit needs enough water to produce chlorine.

What should I check first for E3?

Start by checking that the circulation pump is running, the valves are in the operating position, and there are no leaks or air in the pipes.

Water is reaching the unit but E3 still shows. What now?

Have a technician check the water level detection device, including inspection and cleaning per the manual when needed.

Can I keep running the unit with E3 showing?

No. Never force the unit to run without water. Fix the cause so the system has water normally before use.

RELATED PRODUCTS

WINWINPOOL SHOP

Laswim EC Series Salt Chlorinators

Looking for a Laswim EC Series salt chlorinator, or want to compare models for your pool? See the full product details on our EC Series salt chlorinator page.

View EC Series models and details in one place
Choose the right model for your pool size and usage
Ask our team on LINE before you decide

Need Help With an Initial Diagnosis?

Send us a photo of the display and the installation, and let us know whether the pump is running and water is reaching the unit.

WINWINPOOL Everything For Your Pool
#Winwinpool #Laswim #ECSeries #LaswimE3 #SaltChlorinator #PoolCare

Related Content
Choosing the Right Pool Pump for Your Sand Filter in 2026
Pumps and sand filters are "partners" that must work together in balance. Choosing a pump that delivers water faster than the filter can handle → water passes through the sand too quickly, unable to filter properly,
What is a Drop Panel?  A Drop Panel is a section of the concrete slab that is thickened specifically around the column area. It appears as a depressed (lowered) area or a thickened wing surrounding the column reinforcement.  Its purposes are to:  Increase
What is a Drop Panel? A Drop Panel is a section of the concrete slab that is thickened specifically around the column area. It appears as a depressed (lowered) area or a thickened wing surrounding the column reinforcement. Its purposes are to: Increase the load-bearing capacity of the pool structure Strengthen the slab around the column Reduce and prevent cracking Help prevent water leakage
เครื่องเกลือ Hayward AquaRite 900 ไฟ Power ไม่ติด ต้องตรวจอะไรบ้าง?
The Generating light on a Hayward AquaRite 900 shows chlorine production status. If it is flashing, the water may be too hot or too cold for the unit's operating range. This guide explains the difference between a steady and flashing light, how to check water temperature with the Diagnostic button and a thermometer, and what to know before using SUPER CHLORINATE mode.
icon-messenger
This website uses cookies to enhance performance and provide you with a better user experience. You can read more details at: Privacy Policy and Cookies Policy