-52%
Out of stock

EC16 Series Salt Chlorinator, 16 g/h, for Pools up to 68 m³

SKU : SC-LS-EC16

2 Sold

5.0 / 5 (2 Reviews)

฿24,866
฿11,936

Quantity

Notify me when available

Leave your email here, we will notify you when this product becomes available

Short Description

The EC16 salt chlorinator produces up to 16 g of chlorine per hour and is suitable for pools up to 68 m³. Its compact design requires little installation space and is easy to operate and maintain. The controller is mounted on the cell assembly.

Package dimensions: 16 × 34 × 25.5 cm
Gross weight including packaging: 2.87 kg
Updated: 04/03/2026

Wishlist
รายละเอียดสินค้า
Download
VDO
LASWIM · EC SERIES · EC16

Salt Chlorinator
LASWIM EC16

Maximum output 16 g/h · For pools up to 68 m³ according to the product listing

Integrated controller and cellAlerts and protective functions
EC16
SALT CHLORINATOR
 
Product code: SC-LS-EC16
PRODUCT OVERVIEW

Salt chlorination for small to medium residential pools

The EC16 uses electrolysis to generate sanitizing chlorine from salt dissolved in pool water. Its controller and chlorine-generating cell are integrated to save installation space, while the cell plates are accessible for maintenance. Chlorine production depends on a working circulation and filtration system, and water quality must still be tested regularly.

16 g/hMaximum chlorine output
68 m³Maximum specified pool volume
5 settingsOutput adjustment: 20–100%
1.5Connection size / 50 mm
SPECIFICATIONS

LASWIM EC16 specifications

Model / product codeLASWIM EC16 / SC-LS-EC16
Maximum chlorine output16 grams per hour
Maximum pool volume68 cubic meters (subject to actual operating conditions)
Operating voltage / currentUse only the adapter supplied with the unit. Check the voltage and current on the actual equipment label before connecting power.
Pipe connection1.5 in / 50 mm. Verify the union size on the actual unit before installation.

The 68 m³ figure is the maximum pool size in the reference table, not a guarantee of sufficient chlorine production for every pool. Allow for higher demand in outdoor or heavily used pools and assess the pump run time.

Key features

Adjustable chlorine output
Select from five output levels using the + and − buttons to match the measured chlorine level and the pool's needs.
Boost mode
Operates at maximum output for 8 hours before returning to the previous setting. Check chlorine levels before and after use.
Reduced scale buildup
The automatic cell-cleaning function helps reduce deposits, but the cell still requires periodic inspection.
Alert system
The display shows error codes for conditions such as insufficient water flow or abnormal salt levels.
Operating schedule
The EC Series manual specifies a 1–24 hour operating-time setting. Check the controls on the unit supplied to you.
Setting memory
According to EC Series information, the unit recalls its last operating state when restarted.
INSTALLATION & FIRST USE

Before installation and first use

01 · Plumbing

Install in the circulation line downstream of the pump and filter as directed by the manual. Check the flow direction and ensure sufficient water passes through the cell. Design bypasses and valves to suit the site's piping layout.

02 · Electrical supply

Have a qualified technician check the power supply and supplied adapter. Install residual-current protection and ensure the chlorinator cannot receive power when the pump is stopped.

03 · Installation location

Choose a well-ventilated location and protect electrical components from rain, humidity, and splashing. Leave room to remove the cell plates.

04 · Check water before startup

Measure salinity and water quality before generating chlorine. Start the pump and confirm normal water flow through the unit.

Adding salt and maintaining water quality

The EC Series manual gives a reference salt concentration of approximately 3,500 ppm or 3.5 kg per 1 m³ of water. Use pool-grade sodium chloride without unsuitable additives. Always measure existing salinity first to avoid adding too much salt.

Calculate how much salt to add
Salt to add (kg) = Pool volume (m³) × [3,500 − measured salinity (ppm)] ÷ 1,000
Example: For a 20 m³ pool measuring 2,500 ppm, add approximately 20 kg to reach the target.

Turn off the chlorinator while adding salt, keep the circulation pump running, and spread the salt so it does not collect on the pool floor. The manual recommends circulating the water for 24 hours, then measuring salinity again before switching on the chlorinator. Test free chlorine and pH regularly, and adjust run time or output based on actual readings.

Common alert codes

CodeMeaningInitial checks
E2Water temperature out of rangeCheck water temperature and the sensor.
E3Insufficient water in the cellCheck the pump, valves, trapped air in the piping, and sensor.
E4High salt levelMeasure salinity with a meter before taking corrective action.
E5Low salt levelMeasure salinity before calculating how much salt to add.

For other codes, consult the EC Series manual and contact a technician if the issue cannot be resolved. Never open the housing or repair circuits while the power is on.

Proper cell maintenance

Inspect the cell regularly and clean it if scale builds up. Automatic cleaning helps reduce deposits but does not replace inspection. Before removing the cell, disconnect power, stop the pump, close relevant valves, and release pressure in the pipe. If a cell-cleaning solution is needed, follow the EC Series manual and the solution's safety instructions. Do not scrape the titanium plates with metal tools.

Frequently asked questions

Can the EC16 be used with a 68 m³ pool?

The product listing specifies pools up to 68 m³. However, sun exposure, bather load, chlorine demand, and pump run time must also be considered. For a pool with high demand, assess a higher-output model.

What salt concentration is required?

The EC Series manual lists a normal salt concentration of approximately 3,500 ppm. Measure it before adding salt, and measure again once the salt has dissolved and circulated throughout the pool.

Can the chlorinator run while the pump is stopped?

No. The cell requires sufficient water flow. Arrange the electrical controls so the chlorinator runs only while the circulation pump is operating.

How can I check what is included before ordering?

Confirm the included components with our staff before ordering, as the package contents may vary.

EC Series manual in Thai: Open the operating manual · Technical details are based on LASWIM EC Series information. Check the label on the actual unit delivered.

EC16 chlorine increase: worked examples

How long might it take to raise the chlorine level in pools of different sizes? Use these initial calculations, then adjust run time to suit the actual pool.

A simple calculation

H = (Q × ΔPPM) ÷ Capacity
  • H = Approximate run time (hours)
  • Q = Pool volume (m³)
  • ΔPPM = Desired increase in free chlorine (ppm) = target level − measured level
  • Capacity = Chlorine output; the EC16 is rated at up to 16 g/h.

This formula estimates the theoretical time needed to raise chlorine by the measured difference. It is not a daily run-time setting, because sunlight, swimmers, and contaminants consume chlorine during use.

Calculated examples: three pool sizes

Assume an initial free chlorine level of 0 ppm, a target of 2 ppm, and the EC16 operating at its maximum output of 16 g/h.

Pool volumeCalculationTheoretical time
10 m³(10 × 2) ÷ 161.25 hours
20 m³(20 × 2) ÷ 162.5 hours
68 m³(68 × 2) ÷ 168.5 hours

If measured chlorine is 1 ppm and the target is 2 ppm, use ΔPPM = 1, not 2. Test chlorine again to adjust actual run time.

WINWINPOOL expert tips

  • Frequent use or strong sunlight: test chlorine and adjust production time based on the results.
  • Frequent rain: test free chlorine and pH before changing the run time.
  • Water turning green: check chlorine, pH, and filtration to find the cause. Do not simply aim for 3 ppm without testing the water.
  • Run the chlorinator only while the circulation pump is operating.

In brief

A smaller pool needs less time than a larger pool for the same chlorine increase. This formula provides an initial estimate; set the daily run time based on pool conditions and measured water quality.

Why choose the EC16 from WINWINPOOL?

  • Maximum chlorine output of 16 g/h according to the product listing.
  • Adjustable chlorine output.
  • The product listing specifies pools up to 68 m³, subject to actual operating conditions.
  • Our team can advise on model selection and settings.

Ask about models and product availability

Interested in the EC16 salt chlorinator or need help sizing it for your pool? Chat with WINWINPOOL on LINE @winwinpool.

LASWIM EC Series installation

Ratings & Reviews
There are no ratings and reviews yet. Be the first to comment.
icon-messenger