SKU : SC-LS-EC8
3 Sold
5.0 / 5 (2 Reviews)
Quantity
Short Description
Suitable for pools up to 35 m³. The compact unit requires little installation space and is easy to operate and maintain. The controller is mounted on the cell assembly.
Package dimensions: 16 × 34 × 25.5 cm
Gross weight including packaging: 2.87 kg
Updated: 04/03/2026
Easy to operate · Compact installation · Protection against abnormal water conditions

PRODUCT OVERVIEW
LASWIM EC Plus uses electrolysis to generate a chlorine sanitizer from salt dissolved in pool water. Its controller and cell form one compact unit, reducing installation space and connection points. It is suited to small and medium-sized pools. Regular testing and balancing of pool water are still required.
MODEL COMPARISON
| Model | Maximum chlorine output | Maximum pool volume* | Output voltage | Operating current |
|---|---|---|---|---|
| EC Plus 8 | 8 g/h | 35 m³ | DC 24 V | 4 A |
| EC Plus 12 | 12 g/h | 50 m³ | DC 24 V | 4 A |
| EC Plus 16 | 16 g/h | 68 m³ | DC 24 V | 4 A |
| EC Plus 20 | 20 g/h | 85 m³ | DC 24 V | 4 A |
| EC Plus 30 | 30 g/h | 127 m³ | DC 29 V | 6 A |
*Maximum pool volumes are reference figures from the manufacturers catalog. Allow approximately 2030% extra chlorine output when choosing a model, considering actual use, sunlight, pump run time, and water quality. Check the label and power adapter of the supplied unit before installation.
INSTALLATION GUIDANCE
Install on the pool return line downstream of the pump and filter, following the manufacturers specified flow direction. If a bypass is used, provide a suitable flow-control valve and isolation points for the actual plumbing layout.
02 · Connection sizeCheck that the 1.5 in / 50 mm unions fit the pipework before permanently securing them. Leave enough clearance to remove the cell for maintenance.
Use the power supply specified for the model and install residual-current protection as required by local regulations. Have a qualified installer check its connection to the pump system.
04 · Installation locationChoose a well-ventilated location and protect the unit from rain, strong sunlight, and splashing as directed in the product manual.
Test free chlorine, pH, and actual salinity before adjusting output. The chlorinator does not automatically measure and control every water-quality parameter. If salt is needed, use pool salt meeting the unit manuals requirements. Distribute it and allow it to dissolve throughout the pool before starting chlorine production.
Inspect the cell and any scale at the recommended maintenance intervals. Switch off the power supply and pump, then release pipe pressure before removing parts. If cell-cleaning solution is required, follow the dilution and procedure in the manual for the supplied model, wear protective equipment, and avoid scraping titanium plates with metal.

Images are illustrative. Follow the manual for the supplied model for clearances, plumbing, and electrical connections.
Model specifications and performance figures are based on the LASWIM EC Plus Series catalog. Specifications and included accessories may vary by production batch and market. Verify the label and manual of the supplied unit before installation.