Crystal-clear water, sanitized automatically every day. No more adding chlorine by hand each week.
The cell installs on the return line after the filter, so every drop that passes through it picks up chlorine made from salt before flowing back to the pool. Soft water, no stinging eyes and no harsh chlorine smell. Ideal for home pools, villas and light-commercial pools up to 115 m³.
The pump draws water from the pool and sends it to the filter. Filtered water passes through the inlet valve into the salt cell, where electrolysis turns salt into chlorine, then leaves through the outlet valve and returns to the pool. The bypass valve lets you remove the cell for cleaning while filtration keeps running.
Swipe left or right to see the full diagram
30 frequently asked questions, from choosing a model, adding salt and daily settings to reading status lights, error codes and cleaning the cell. Pick a category below to see the answers.
Salt chlorinators for residential and light-commercial pools, with self-cleaning titanium cells (polarity reversal) and an IPX4 water-resistant control box.
SSC15
15g/h
SSC25
25g/h
SSC50
45g/h (actual)
Power input 220–240 VAC 50/60 Hz. Connects to 1.5" or 2" pipe with the supplied unions. Not sure of your pool volume? See how to calculate it in the Sizing & Install tab.
Calculate pool volume and daily chlorine demand, and install correctly per the manual.
There are three output sizes: SSC15 (15 g/h), SSC25 (25 g/h) and SSC50 (45 g/h actual output). Each comes in three versions: -E (no timer; runs with the pump), -T (built-in timer plus a pump power outlet up to 1.5 HP) and -TLT (built-in timer plus a 12 V transformer for pool lights).
First calculate your pool volume in cubic metres (m³), then compare it with the model specs. Concrete pools use a slightly lower limit than fiberglass pools because concrete walls have a higher chlorine demand.
Example: 5 × 10 × 1.5 = 75 m³. Round pool: 3.14 × radius² × average depth. For a freeform pool, split it into rectangles and circles and add them together (1 m³ = 1,000 litres).
The EMAUX manual uses a minimum of 2 mg of chlorine per litre (0.002 g/L).
Example: a 65 m³ pool = 65,000 L × 0.002 = 130 g per day. An SSC15 (15 g/h) needs about 8.7 hours of production; an SSC25 (25 g/h) about 5.2 hours. In very hot weather or with heavy bather load, demand rises, so increase run time or add shock chlorine.
Choose the larger model and set the System Control knob below 100%. The unit won't need to run at full power all the time, the cell works fewer hours, and you keep reserve capacity for hot spells or pool parties.
Yes, by installing several units so their combined output matches the pool volume. Cell positions and return-line splits must be designed so water flows evenly through every cell. We recommend having the WinWin Pool engineering team design the system.
Water passes through the pump, filter and heater first, then into the salt cell on the bypass. To remove the cell for cleaning, switch off the chlorinator, then close the inlet and outlet valves. Filtration continues through the main valve.
Keeping the right salt level is the biggest factor in a long cell life.
SSC15 and SSC25: 3,000 – 4,000 ppm. SSC50: 4,000 – 5,000 ppm. Do not exceed 5,000 ppm, or the unit will raise a high-salt warning and reduce chlorine output on its own.
Easy rule: 1,000 ppm = 1 kg per 1 m³ of water.
| Pool volume (m³) | 3,500 ppm (kg) | 4,000 ppm (kg) | 4,500 ppm (kg) |
|---|---|---|---|
| 20 | 70 | 80 | 90 |
| 30 | 105 | 120 | 135 |
| 45 | 158 | 180 | 203 |
| 50 | 175 | 200 | 225 |
| 70 | 245 | 280 | 315 |
| 75 | 263 | 300 | 338 |
| 100 | 350 | 400 | 450 |
| 115 | 403 | 460 | 518 |
We recommend targeting 3,500 ppm for SSC15/SSC25 and 4,500 ppm for SSC50 (mid-range). This table applies to fresh tap water with no salt yet.
Example: a 50 m³ pool reads 2,800 ppm and you want 3,500 ppm → (3,500 − 2,800) × 50 ÷ 1,000 = 35 kg. Add it in stages, then re-test after 24 hours of circulation.
Use sodium chloride of 99% purity or higher (pool salt). Do not use:
Impurities in the salt shorten cell life.
Salt isn't consumed when chlorine is produced, because chlorine turns back into salt after it sanitizes the water. Salt is lost through backwashing, splash-out, draining and dilution from rain. Test the salt level once a month, and after heavy rain or a large top-up of fresh water.
The only fix is to drain some water and refill with fresh water.
Example: reading 6,000 ppm, target 4,500 ppm → drain about 25% and refill. Meanwhile, the unit automatically reduces chlorine output to prevent overload.
The chemistry you manage yourself, run times and the controls on the unit.
The chlorinator only produces chlorine; it does not balance your water. You need to test and adjust these levels yourself.
| Parameter | Recommended range |
|---|---|
| Free chlorine | 1.0 – 3.0 ppm |
| pH | 7.2 – 7.6 |
| Cyanuric acid (stabilizer) | 30 – 50 ppm |
| Total alkalinity | 80 – 120 ppm |
| Calcium hardness | 200 – 400 ppm |
| Metals (copper, iron, etc.) | 0 ppm |
The unit must always run together with the pump. Work out the hours from your daily chlorine demand (see Q4 in the Sizing tab), then adjust based on actual chlorine readings: below 1 ppm, add hours or raise the %; above 3 ppm, reduce. On -T models, set the timer so the pump and chlorinator switch on and off together.
The System Control knob sets what share of each hour the cell produces chlorine.
In normal operation, the number on the display is the chlorine output %. A green System Control light means the cell is producing; a red light means it is in a rest period.
After backwashing, set the valve back to Filtration before switching the chlorinator on again.
The manual recommends increasing the unit's run time or adding shock chlorine (granular, tablet or liquid), which is safe to use alongside the salt chlorinator. Keep stabilizer at 30 – 50 ppm to reduce chlorine loss from sunlight.
Electrolysis of salt produces sodium hydroxide (NaOH) as a by-product, which pushes pH upward. Test pH at least once a week and add pH-reducing acid to keep it at 7.2 – 7.6. High pH makes chlorine less effective and causes scale to build up on the cell faster.
Winter Mode reduces chlorine output to 85% of the set level. Use it when the water is cold, which may trigger a red warning light. Most pools in Thailand rarely need it, except during cool spells in mountain areas.
Read the warning lights correctly before acting to avoid damaging the cell.
| Operation 1 | Operation 2 | Meaning | What to do |
|---|---|---|---|
| Green | Green | Normal operation, salt level OK | No action needed |
| Green | Red | Low salt / scale on cell / cold water | Test salt; add if low, check and clean the cell if normal |
| Red | Green | Salt too high | Test salt; if above 5,000 ppm, drain some water |
| Red | Red | Very low salt / heavy scale / very cold water | Stop the unit and fix it now, or the cell will be damaged |
Don't pour in more salt straight away. Test the salt level with a meter or test strips first. If salt is low, add it as in Q10 in the Salt tab. If salt is normal but the lights stay red, scale on the titanium plates is the usual cause, so clean the cell as in Q28 in the Care tab. If gas output is still weak after cleaning, the cell may be at the end of its life. Contact WinWin Pool for an inspection.
The No Flow light comes on when the water level inside the cell housing drops below the gas sensor. The system stops the pump and chlorinator automatically for safety. Check in this order:
| Code | Meaning | Fix |
|---|---|---|
| ER2 | Terminal temperature too high (overheat protection) | Switch off and let it cool, tighten the cell cable terminal nuts, then switch on again |
| ER3 | Temperature sensor disconnected | Check that the sensor cable is not loose or unplugged |
| ER4 | AC input power fault | Check the transformer output wiring or a blown fuse |
ER2 can be caused by very high salt, extreme heat or poor ventilation around the control box. Install the box under a sun shade or in a well-ventilated pump room.
A display stuck on 888 means the internal fuse needs replacing, usually because of unstable power. We recommend fitting a breaker and a voltage stabilizer ahead of the unit. If the display doesn't light up at all, check the plug and power supply, the breaker, and that the cable between the control box and the cell is firmly connected at both ends.
| Cause | Fix |
|---|---|
| System Control set too low | Raise the % or turn it to maximum |
| Timer is cutting operation | Adjust the timer settings (-T models) |
| Low salt | Add salt |
| Salt too high | The unit limits output; drain some water |
| Scale on the cell | Clean the cell |
| Blown fuse | Unplug and replace the fuse |
| Cold water | Turn on Winter Mode |
| Low stabilizer / strong sun / high pH | Balance the water as in Q15 |
| No gas even after cleaning | The titanium plates may be worn out; replace the cell |
Correct care keeps the cell working longer and within warranty terms.
The unit reverses polarity every 8 hours to reduce scale, but hard water or high pH can still leave white limescale deposits. Inspect the titanium plates regularly and clean them when you see scale.
Cell life depends on operating hours, how well salt and water chemistry are maintained, and how often scale is cleaned. Running with low salt (below 2,500 ppm) wears the titanium coating fastest. Signs a cell is near the end of its life: little or no gas even after cleaning, and red lights that stay on even though the salt level is correct. WinWin Pool stocks genuine cells and spare parts for every SSC Series model.
The warranty covers defects in materials and workmanship under normal use, for the original purchaser buying through an authorized dealer. Consumable parts are excluded. The warranty does not apply in cases of:
The warranty period is as stated on your WinWin Pool warranty card.
The WinWin Pool team can help you choose a model, calculate salt and service your EMAUX SSC Series, with genuine cells and spare parts for every model.